An Uncontrolled Resource Consumption vulnerability in the handling of IPv6 neighbor state change events in Juniper Networks Junos OS allows an adjacent attacker to cause a memory leak in the Flexible PIC Concentrator (FPC) of an ACX5448 router. The continuous flapping of an IPv6 neighbor with specific timing will cause the FPC to run out of resources, leading to a Denial of Service (DoS) condition. Once the condition occurs, further packet processing will be impacted, creating a sustained Denial of Service (DoS) condition, requiring a manual PFE restart to restore service. The following error messages will be seen after the FPC resources have been exhausted: fpc0 DNX_NH::dnx_nh_tag_ipv4_hw_install(),3135: dnx_nh_tag_ipv4_hw_install: BCM L3 Egress create object failed for NH 602 (-14:No resources for operation), BCM NH Params: unit:0 Port:41, L3_INTF:0 Flags: 0x40 fpc0 DNX_NH::dnx_nh_tag_ipv4_hw_install(),3135: dnx_nh_tag_ipv4_hw_install: BCM L3 Egress create object failed for NH 602 (-14:No resources for operation), BCM NH Params: unit:0 Port:41, L3_INTF:0 Flags: 0x40 fpc0 DNX_NH::dnx_nh_tag_ipv4_hw_install(),3135: dnx_nh_tag_ipv4_hw_install: BCM L3 Egress create object failed for NH 602 (-14:No resources for operation), BCM NH Params: unit:0 Port:41, L3_INTF:0 Flags: 0x40 fpc0 DNX_NH::dnx_nh_tag_ipv4_hw_install(),3135: dnx_nh_tag_ipv4_hw_install: BCM L3 Egress create object failed for NH 602 (-14:No resources for operation), BCM NH Params: unit:0 Port:41, L3_INTF:0 Flags: 0x40 This issue only affects the ACX5448 router. No other products or platforms are affected by this vulnerability. This issue affects Juniper Networks Junos OS on ACX5448: 18.4 versions prior to 18.4R3-S10; 19.1 versions prior to 19.1R3-S5; 19.2 versions prior to 19.2R1-S8, 19.2R3-S2; 19.3 versions prior to 19.3R2-S6, 19.3R3-S2; 19.4 versions prior to 19.4R1-S3, 19.4R2-S2, 19.4R3; 20.1 versions prior to 20.1R2; 20.2 versions prior to 20.2R1-S1, 20.2R2.

CWE-400CWE-772

What to do

None of the Linux distributions or Windows releases we track list an affected package for this CVE. Check the vendor-reported products below.

Is your server affected? One read-only command checks every installed package against this CVE and all others, using each vendor's fixed versions. Get started or get a free API key.

curl -sS "https://api.cvefocus.com/v1/check?format=text" -H "Authorization: Bearer $CVEFOCUS_KEY" \
  -H "Content-Type: text/plain" --data-binary @inventory.txt

What the vendor says

As published in the CVE record by juniper, the CVE's assigner (usually the vendor). Check the vendor's advisory before acting.

Solution: The following software releases have been updated to resolve this specific issue: Junos OS 18.4R3-S10, 19.1R3-S5, 19.2R1-S8, 19.2R3-S2, 19.3R2-S6, 19.3R3-S2, 19.4R1-S3, 19.4R2-S2, 19.4R3, 20.1R2, 20.2R1-S1, 20.2R2, 20.3R1, and all subsequent releases.

Workaround: There are no known workarounds for this issue.

References

About this page

Compiled by CVEfocus from the CVE List, the security data and VEX statements of Ubuntu, Debian, Red Hat, AlmaLinux, Rocky Linux and Microsoft, CISA's Known Exploited Vulnerabilities catalog and FIRST EPSS, refreshed several times a day (data status). Information only; see the disclaimer. Official record: cve.org · NVD.