CVE-2022-31218Drive Composer Link Following Local Privilege Escalation Vulnerability
Vulnerabilities in the Drive Composer allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Drive Composer installer file allows a low-privileged user to run a "repair" operation on the product.
What to do
None of the Linux distributions or Windows releases we track list an affected package for this CVE. Check the vendor-reported products below.
Is your server affected? One read-only command checks every installed package against this CVE and all others, using each vendor's fixed versions. Get started or get a free API key.
curl -sS "https://api.cvefocus.com/v1/check?format=text" -H "Authorization: Bearer $CVEFOCUS_KEY" \ -H "Content-Type: text/plain" --data-binary @inventory.txt
What the vendor says
As published in the CVE record by ABB, the CVE's assigner (usually the vendor). Check the vendor's advisory before acting.
- ABB Drive Composer entry: affected: 2.0 to before unspecified, unspecified to 2.7
- ABB Drive Composer pro: affected: 2.0 to before unspecified, unspecified to 2.7
- ABB Automation Builder: affected: 1.1.0 to before unspecified, unspecified to 2.5.0
- ABB Mint WorkBench: affected: build to 5866
Solution: The problem is corrected in the following product versions: Drive Composer entry version 2.7.1 Drive Composer pro version 2.7.1 Customers using Drive composer pro integrated in ABB Automation Builder should refer to section “Workarounds” in this document. Mint WorkBench Build 5868 ABB recommends that customers apply the update at earliest convenience. Updated versions of Drive Composer are available immediately. ABB Automation Builder 2.5.1 and Mint WorkBench Build 5868 will be available before or during Q3/2022.
Workaround: ABB has tested the following workarounds. Although these workarounds will not correct the underlying vulnerability, they can help block known attack vectors. When a workaround reduces functionality, this is identified below as “Impact of workaround”. With ABB Automation Builder it is possible to change the version of Drive Composer used so it is not mandatory to update that application immediately. Steps: 1) Install or upgrade Drive Composer pro version to 2.7.1 2) In ABB Automation Builder Options, select External tools. 3) At Drive composer pro-line, select Custom and select the installed Drive Composer pro version 2.7.1 executable typically in C:\Program Files (x86)\DriveWare\Drive Composer pro\2.7 Alternatively, users are able to remove the vulnerable Drive Composer for ABB Automation Builder. This can be done either from ABB Automation Builder Installation manager or from Windows…
References
About this page
Compiled by CVEfocus from the CVE List, the security data and VEX statements of Ubuntu, Debian, Red Hat, AlmaLinux, Rocky Linux and Microsoft, CISA's Known Exploited Vulnerabilities catalog and FIRST EPSS, refreshed several times a day (data status). Information only; see the disclaimer. Official record: cve.org · NVD.