CVE-2022-31486Command injection via Advanced Networking route add functionality
An authenticated attacker can send a specially crafted route to the “edit_route.cgi” binary and have it execute shell commands. This vulnerability impacts products based on HID Mercury Intelligent Controllers LP1501, LP1502, LP2500, LP4502, and EP4502 which contain firmware versions prior to 1.303 for the LP series and 1.297 for the EP series. An attacker with this level of access on the device can monitor all communications sent to and from this device, modify onboard relays, change configuration files, or cause the device to become unstable.
What to do
None of the Linux distributions or Windows releases we track list an affected package for this CVE. Check the vendor-reported products below.
Is your server affected? One read-only command checks every installed package against this CVE and all others, using each vendor's fixed versions. Get started or get a free API key.
curl -sS "https://api.cvefocus.com/v1/check?format=text" -H "Authorization: Bearer $CVEFOCUS_KEY" \ -H "Content-Type: text/plain" --data-binary @inventory.txt
What the vendor says
As published in the CVE record by Carrier, the CVE's assigner (usually the vendor). Check the vendor's advisory before acting.
- LenelS2 LNL-X2210: affected: ALL to before 1.303; fixed in
1.303 - LenelS2 LNL-X2220: affected: ALL to before 1.303; fixed in
1.303 - LenelS2 LNL-X3300: affected: ALL to before 1.303; fixed in
1.303 - LenelS2 LNL-X4420: affected: ALL to before 1.303; fixed in
1.303 - LenelS2 LNL-4420: affected: ALL to before 1.297; fixed in
1.297 - LenelS2 S2-LP-1501: affected: ALL to before 1.303; fixed in
1.303 - LenelS2 S2-LP-1502: affected: ALL to before 1.303; fixed in
1.303 - LenelS2 S2-LP-2500: affected: ALL to before 1.303; fixed in
1.303 - LenelS2 S2-LP-4502: affected: ALL to before 1.303; fixed in
1.303 - HID Mercury LP1501: affected: ALL to before 1.303; fixed in
1.303 - HID Mercury LP1502: affected: ALL to before 1.303; fixed in
1.303 - HID Mercury LP2500: affected: ALL to before 1.303; fixed in
1.303
Solution: Update to the latest version of firmware
Workaround: Disable the controller's Web Server. When the controller is configured to disable web access, you cannot remotely login into the controller’s web page. 1. Login to controller web pages 2. Go to “Users” Tab 3. Near bottom of the Users page, check option to “Disable Web Server” 4. Then select “Submit” at the bottom of the page 5. Then select “Apply Settings” tab 6. And on that page, select button “Apply Settings, Reboot” The Controller will apply the new setting and reboot. Web login will be disabled until switch 1 is physically turned ON, on the controller.
References
About this page
Compiled by CVEfocus from the CVE List, the security data and VEX statements of Ubuntu, Debian, Red Hat, AlmaLinux, Rocky Linux and Microsoft, CISA's Known Exploited Vulnerabilities catalog and FIRST EPSS, refreshed several times a day (data status). Information only; see the disclaimer. Official record: cve.org · NVD.