CVEfocus › CVE database › CVE-2022-41648

CVE-2022-41648

CVSS 9.2 CriticalEPSS 1.0% (higher than 62% of CVEs)Published 2022-10-28Updated 2025-10-13Assigner: icscert

The HEIDENHAIN Controller TNC 640 NC software Version 340590 07 SP5, is vulnerable to improper authentication in its DNC communication for CNC machines. Authentication is not enabled by default for DNC communication. This vulnerability may allow an attacker to deny service on the production line, steal sensitive data from the production line, and alter any products created by the production line. Note: CNC machines running the TNC 640 controller require DNC to be enabled for DNC communication to be present.

CWE-1188

What to do

None of the Linux distributions or Windows releases we track list an affected package for this CVE. Check the vendor-reported products below.

Is your server affected? One read-only command checks every installed package against this CVE and all others, using each vendor's fixed versions. Get started or get a free API key.

curl -sS "https://api.cvefocus.com/v1/check?format=text" -H "Authorization: Bearer $CVEFOCUS_KEY" \
  -H "Content-Type: text/plain" --data-binary @inventory.txt

What the vendor says

As published in the CVE record by icscert, the CVE's assigner (usually the vendor). Check the vendor's advisory before acting.

Solution: HEIDENHAIN has identified the following specific workarounds and mitigations users can apply to reduce risk: * Block LSV2 and DNC communication using the integrated firewall in the controller's operating system. * Use zone firewalls to isolate and segment the network of the affected devices. * Ask your machinery vendor (running HEIDENHAIN controllers) for updates to a recent software version, where SSH tunneling is standard.

Workaround: HEIDENHAIN has identified the following specific workarounds and mitigations users can apply to reduce risk: * Block LSV2 and DNC communication using the integrated firewall in the controller's operating system. * Use zone firewalls to isolate and segment the network of the affected devices. * Ask machinery vendor (running HEIDENHAIN controllers) for updates to a recent software version, where SSH tunneling is standard.

References

About this page

Compiled by CVEfocus from the CVE List, the security data and VEX statements of Ubuntu, Debian, Red Hat, AlmaLinux, Rocky Linux and Microsoft, CISA's Known Exploited Vulnerabilities catalog and FIRST EPSS, refreshed several times a day (data status). Information only; see the disclaimer. Official record: cve.org · NVD.