CVE-2023-24512On affected platforms running Arista EOS, an authorized attacker with permissions to…
On affected platforms running Arista EOS, an authorized attacker with permissions to perform gNMI requests could craft a request allowing it to update arbitrary configurations in the switch. This situation occurs only when the Streaming Telemetry Agent (referred to as the TerminAttr agent) is enabled and gNMI access is configured on the agent. Note: This gNMI over the Streaming Telemetry Agent scenario is mostly commonly used when streaming to a 3rd party system and is not used by default when streaming to CloudVision
What to do
None of the Linux distributions or Windows releases we track list an affected package for this CVE. Check the vendor-reported products below.
Is your server affected? One read-only command checks every installed package against this CVE and all others, using each vendor's fixed versions. Get started or get a free API key.
curl -sS "https://api.cvefocus.com/v1/check?format=text" -H "Authorization: Bearer $CVEFOCUS_KEY" \ -H "Content-Type: text/plain" --data-binary @inventory.txt
What the vendor says
As published in the CVE record by Arista, the CVE's assigner (usually the vendor). Check the vendor's advisory before acting.
- Arista Networks Terminattr: affected: 1.23.0, unspecified to 1.19.5, 1.24.0 to 1.24.3, 1.22.0 to 1.22.1
Solution: While the steps listed above resolve the issue, the recommended long term solution is to upgrade to a remediated software version at your earliest convenience. Arista recommends customers move to the latest version of each release that contains all the fixes listed below. There are two possible solutions: Upgrade the Streaming Telemetry Agent Customers can upgrade the Streaming Telemetry Agent to a fixed version, following the directions in https://arista.my.site.com/AristaCommunity/s/article/terminattr-upgrade-downgrade. Fixes are available in the following supported release trains: TerminAttr 1.25.0 and later Terminattr versions Users of 1.24.X and 1.23.X TerminAttr releases should upgrade to TerminAttr 1.25.0 or later. TerminAttr 1.22.2 and later version in the TerminAttr 1.22.X train TerminAttr 1.19.6 and later versions in the TerminAttr 1.19.X train
Workaround: The streaming telemetry agent can be configured in gRPC read-only mode by specifying -grpcreadonly as part of its configuration. For instance as follows: switch# daemon TerminAttr exec /usr/bin/TerminAttr -grpcreadonly -grpcaddr=... <other options...> no shutdown If TerminAttr is running, it must be restarted for the configuration to take effect. This can be done as follows: switch# daemon TerminAttr shutdown wait-for-warmup no shutdown
References
About this page
Compiled by CVEfocus from the CVE List, the security data and VEX statements of Ubuntu, Debian, Red Hat, AlmaLinux, Rocky Linux and Microsoft, CISA's Known Exploited Vulnerabilities catalog and FIRST EPSS, refreshed several times a day (data status). Information only; see the disclaimer. Official record: cve.org · NVD.