CVE-2023-27465
A vulnerability has been identified in SIMOTION C240 (All versions >= V5.4 < V5.5 SP1), SIMOTION C240 PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D410-2 DP (All versions >= V5.4 < V5.5 SP1), SIMOTION D410-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D425-2 DP (All versions >= V5.4 < V5.5 SP1), SIMOTION D425-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D435-2 DP (All versions >= V5.4 < V5.5 SP1), SIMOTION D435-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D445-2 DP/PN (All versions >= V5.4), SIMOTION D445-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D455-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION P320-4 E (All versions >= V5.4), SIMOTION P320-4 S (All versions >= V5.4). When operated with Security Level Low the device does not protect access to certain services relevant for debugging. This could allow an unauthenticated attacker to extract confidential technology object (TO) configuration from the device.
What to do
None of the Linux distributions or Windows releases we track list an affected package for this CVE. Check the vendor-reported products below.
Is your server affected? One read-only command checks every installed package against this CVE and all others, using each vendor's fixed versions. Get started or get a free API key.
curl -sS "https://api.cvefocus.com/v1/check?format=text" -H "Authorization: Bearer $CVEFOCUS_KEY" \ -H "Content-Type: text/plain" --data-binary @inventory.txt
What the vendor says
As published in the CVE record by siemens, the CVE's assigner (usually the vendor). Check the vendor's advisory before acting.
- Siemens SIMOTION C240: affected: All versions >= V5.4 < V5.5 SP1
- Siemens SIMOTION C240 PN: affected: All versions >= V5.4 < V5.5 SP1
- Siemens SIMOTION D410-2 DP: affected: All versions >= V5.4 < V5.5 SP1
- Siemens SIMOTION D410-2 DP/PN: affected: All versions >= V5.4 < V5.5 SP1
- Siemens SIMOTION D425-2 DP: affected: All versions >= V5.4 < V5.5 SP1
- Siemens SIMOTION D425-2 DP/PN: affected: All versions >= V5.4 < V5.5 SP1
- Siemens SIMOTION D435-2 DP: affected: All versions >= V5.4 < V5.5 SP1
- Siemens SIMOTION D435-2 DP/PN: affected: All versions >= V5.4 < V5.5 SP1
- Siemens SIMOTION D445-2 DP/PN: affected: All versions >= V5.4
- Siemens SIMOTION D445-2 DP/PN: affected: All versions >= V5.4 < V5.5 SP1
- Siemens SIMOTION D455-2 DP/PN: affected: All versions >= V5.4 < V5.5 SP1
- Siemens SIMOTION P320-4 E: affected: All versions >= V5.4
References
About this page
Compiled by CVEfocus from the CVE List, the security data and VEX statements of Ubuntu, Debian, Red Hat, AlmaLinux, Rocky Linux and Microsoft, CISA's Known Exploited Vulnerabilities catalog and FIRST EPSS, refreshed several times a day (data status). Information only; see the disclaimer. Official record: cve.org · NVD.