CVE-2023-30755
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-7 LTE (All versions < V3.5.20), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.5.20), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMATIC WinCC Runtime Advanced (All versions), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.4.8), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.4.8). The web server of the affected devices do not properly handle the shutdown or reboot request, which could lead to the clean up of certain resources. This could allow a remote attacker with elevated privileges to cause a denial of service condition in the system.
What to do
None of the Linux distributions or Windows releases we track list an affected package for this CVE. Check the vendor-reported products below.
Is your server affected? One read-only command checks every installed package against this CVE and all others, using each vendor's fixed versions. Get started or get a free API key.
curl -sS "https://api.cvefocus.com/v1/check?format=text" -H "Authorization: Bearer $CVEFOCUS_KEY" \ -H "Content-Type: text/plain" --data-binary @inventory.txt
What the vendor says
As published in the CVE record by siemens, the CVE's assigner (usually the vendor). Check the vendor's advisory before acting.
- Siemens SIMATIC CP 1242-7 V2 (incl. SIPLUS variants): affected: before V3.5.20
- Siemens SIMATIC CP 1243-1 (incl. SIPLUS variants): affected: before V3.5.20
- Siemens SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants): affected: before V3.5.20
- Siemens SIMATIC CP 1243-1 IEC (incl. SIPLUS variants): affected: before V3.5.20
- Siemens SIMATIC CP 1243-7 LTE: affected: before V3.5.20
- Siemens SIMATIC CP 1243-8 IRC: affected: before V3.5.20
- Siemens SIMATIC HMI Comfort Panels (incl. SIPLUS variants): affected: All versions
- Siemens SIMATIC IPC DiagBase: affected: all versions
- Siemens SIMATIC IPC DiagMonitor: affected: All versions
- Siemens SIMATIC WinCC Runtime Advanced: affected: All versions
- Siemens SIPLUS TIM 1531 IRC: affected: before V2.4.8
- Siemens TIM 1531 IRC: affected: before V2.4.8
References
About this page
Compiled by CVEfocus from the CVE List, the security data and VEX statements of Ubuntu, Debian, Red Hat, AlmaLinux, Rocky Linux and Microsoft, CISA's Known Exploited Vulnerabilities catalog and FIRST EPSS, refreshed several times a day (data status). Information only; see the disclaimer. Official record: cve.org · NVD.