CVE-2023-38380
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543-1 (6GK7543-1AX00-0XE0) (All versions < V3.0.37), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SINAMICS S210 (6SL5...) (All versions >= V6.1 < V6.1 HF2), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1543-1 (6AG1543-1AX00-2XE0) (All versions < V3.0.37). The webserver implementation of the affected products does not correctly release allocated memory after it has been used. An attacker with network access could use this vulnerability to cause a denial-of-service condition in the webserver of the affected product.
What to do
None of the Linux distributions or Windows releases we track list an affected package for this CVE. Check the vendor-reported products below.
Is your server affected? One read-only command checks every installed package against this CVE and all others, using each vendor's fixed versions. Get started or get a free API key.
curl -sS "https://api.cvefocus.com/v1/check?format=text" -H "Authorization: Bearer $CVEFOCUS_KEY" \ -H "Content-Type: text/plain" --data-binary @inventory.txt
What the vendor says
As published in the CVE record by siemens, the CVE's assigner (usually the vendor). Check the vendor's advisory before acting.
- Siemens SIMATIC CP 1242-7 V2 (incl. SIPLUS variants): affected: before V3.4.29
- Siemens SIMATIC CP 1243-1 (incl. SIPLUS variants): affected: before V3.4.29
- Siemens SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants): affected: all versions
- Siemens SIMATIC CP 1243-1 IEC (incl. SIPLUS variants): affected: before V3.4.29
- Siemens SIMATIC CP 1243-7 LTE: affected: before V3.4.29
- Siemens SIMATIC CP 1243-8 IRC: affected: before V3.4.29
- Siemens SIMATIC CP 1542SP-1: affected: before V2.3
- Siemens SIMATIC CP 1542SP-1 IRC: affected: before V2.3
- Siemens SIMATIC CP 1543-1: affected: before V3.0.37
- Siemens SIMATIC CP 1543SP-1: affected: before V2.3
- Siemens SINAMICS S210 (6SL5...): affected: V6.1 to before V6.1 HF2
- Siemens SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL: affected: before V2.3
References
- https://cert-portal.siemens.com/productcert/pdf/ssa-693975.pdf
- https://cert-portal.siemens.com/productcert/html/ssa-693975.html
- https://cert-portal.siemens.com/productcert/html/ssa-139628.html
- https://cert-portal.siemens.com/productcert/html/ssa-625862.html
About this page
Compiled by CVEfocus from the CVE List, the security data and VEX statements of Ubuntu, Debian, Red Hat, AlmaLinux, Rocky Linux and Microsoft, CISA's Known Exploited Vulnerabilities catalog and FIRST EPSS, refreshed several times a day (data status). Information only; see the disclaimer. Official record: cve.org · NVD.