CVE-2024-8000On affected platforms running Arista EOS with 802.1X configured, certain conditions may…
On affected platforms running Arista EOS with 802.1X configured, certain conditions may occur where a dynamic ACL is received from the AAA server resulting in only the first line of the ACL being installed after an Accelerated Software Upgrade (ASU) restart. Note: supplicants with pending captive-portal authentication during ASU would be impacted with this bug.
What to do
None of the Linux distributions or Windows releases we track list an affected package for this CVE. Check the vendor-reported products below.
Is your server affected? One read-only command checks every installed package against this CVE and all others, using each vendor's fixed versions. Get started or get a free API key.
curl -sS "https://api.cvefocus.com/v1/check?format=text" -H "Authorization: Bearer $CVEFOCUS_KEY" \ -H "Content-Type: text/plain" --data-binary @inventory.txt
What the vendor says
As published in the CVE record by Arista, the CVE's assigner (usually the vendor). Check the vendor's advisory before acting.
- Arista Networks EOS: affected: 4.32.0 to 4.32.4M, 4.31.0 to 4.31.5M, 4.30.0 to 4.30.8M
Solution: The recommended resolution is to upgrade to a remediated software version at your earliest convenience. Arista recommends customers move to the latest version of each release that contains all the fixes listed below. For more information about upgrading see EOS User Manual: Upgrades and Downgrades https://www.arista.com/en/um-eos/eos-upgrades-and-downgrades . CVE-2024-8000 has been fixed in the following releases: * 4.33.0M and above * 4.32.5M and above releases in the 4.32.x train * 4.31.6M and above releases in the 4.31.x train * 4.30.9M and above releases in the 4.30.x train
Workaround: The workaround is to re-authenticate each supplicant. This can be done by running the command “dot1x re-authenticate” on the interface post ASU. Alternatively, if the reauthentication timer is enabled, the ACL will be correctly reprogrammed once the timer has expired and re-authentication occurs. switch(Ethernet 1)#dot1x re-authenticate Alternatively, flapping the interface will trigger reauthentication of the supplicants and correct the ACL which is installed for each mac on that interface. switch(Ethernet 1)#shut switch(Ethernet 1)#no shut In both cases mentioned, we can verify that reauth has been triggered by checking the output of `show logging` to show the supplicant has been successfully authenticated and `show ip access-lists` to verify the ACL is installed correctly. switch(Ethernet 1)#show logging Aug 24 07:12:05 switch Dot1x: DOT1X-6-SUPPLICANT_AUTHENTICATED: Supplicant with…
References
About this page
Compiled by CVEfocus from the CVE List, the security data and VEX statements of Ubuntu, Debian, Red Hat, AlmaLinux, Rocky Linux and Microsoft, CISA's Known Exploited Vulnerabilities catalog and FIRST EPSS, refreshed several times a day (data status). Information only; see the disclaimer. Official record: cve.org · NVD.