CVEfocus › CVE database › CVE-2025-1259

CVE-2025-1259On affected platforms running Arista EOS with OpenConfig configured, a gNOI request can…

CVSS 7.7 HighEPSS 0.6% (higher than 42% of CVEs)Published 2025-03-04Updated 2025-03-04Assigner: Arista

On affected platforms running Arista EOS with OpenConfig configured, a gNOI request can be run when it should have been rejected. This issue can result in users retrieving data that should not have been available

CWE-284

What to do

None of the Linux distributions or Windows releases we track list an affected package for this CVE. Check the vendor-reported products below.

Is your server affected? One read-only command checks every installed package against this CVE and all others, using each vendor's fixed versions. Get started or get a free API key.

curl -sS "https://api.cvefocus.com/v1/check?format=text" -H "Authorization: Bearer $CVEFOCUS_KEY" \
  -H "Content-Type: text/plain" --data-binary @inventory.txt

What the vendor says

As published in the CVE record by Arista, the CVE's assigner (usually the vendor). Check the vendor's advisory before acting.

Solution: The recommended resolution is to upgrade to a remediated software version at your earliest convenience. Arista recommends customers move to the latest version of each release that contains all the fixes listed below. For more information about upgrading see EOS User Manual: Upgrades and Downgrades https://www.arista.com/en/um-eos/eos-upgrades-and-downgrades CVE-2025-1259 is fixed in the following releases: * 4.33.2 and later releases in the 4.33.x train * 4.32.4 and later releases in the 4.32.x train * 4.31.6 and later releases in the 4.31.x train * 4.30.9 and later releases in the 4.30.x train * 4.29.10 and later releases in the 4.29.x train * 4.28.13 and later releases in the 4.28.x train

Workaround: For releases with gNSI Authz (EOS 4.31.0F and later releases), the gNOI RPC’s can be blocked using gNSI Authz. First enable gNSI Authz service by adding the following config: switch(config)#management api gnsi switch(config-mgmt-api-gnsi)#service authz (config-mgmt-api-gnsi)#transport gnmi [NAME] Where [NAME] is the name of the running gNMI transport which gNSI will run on. Adding this config will cause the named gNMI transport to reload. Next update the authz policy to block access to the TransferToRemote RPC. This can be done directly on the system by updating the Authz policy file and waiting at least 10 seconds for OpenConfig to reload the changes. Note this will replace any existing authz policies located at /persist/sys/gnsi/authz/policy.json For CVE-2025-1259 the following CLI command (highlighted in yellow following the switch prompt) can be run which will disable all gNOI Get…

References

About this page

Compiled by CVEfocus from the CVE List, the security data and VEX statements of Ubuntu, Debian, Red Hat, AlmaLinux, Rocky Linux and Microsoft, CISA's Known Exploited Vulnerabilities catalog and FIRST EPSS, refreshed several times a day (data status). Information only; see the disclaimer. Official record: cve.org · NVD.