CVE-2025-14097Remote Code Execution Vulnerability in Radiometer Products
A vulnerability in the application software of multiple Radiometer products may allow remote code execution and unauthorized device management when specific internal conditions are met. Exploitation requires that a remote connection is established with additional information obtained through other means. The issue is caused by a weakness in the analyzer’s application software. Other related CVE's are CVE-2025-14095 & CVE-2025-14096. Affected customers have been informed about this vulnerability. This CVE is being published to provide transparency. Required Configuration for Exposure: Affected application software version is in use and remote support feature is enabled in the analyzer. Temporary work Around: If the network is not considered secure, please remove the analyzer from the network. Permanent solution: Customers should ensure the following: • The network is secure, and access follows best practices. Local Radiometer representatives will contact all affected customers to discuss a permanent solution. Exploit Status: Researchers have provided working proof-of-concept (PoC). Radiometer is not aware of any publicly available exploits at the time of this publication.
What to do
None of the Linux distributions or Windows releases we track list an affected package for this CVE. Check the vendor-reported products below.
Is your server affected? One read-only command checks every installed package against this CVE and all others, using each vendor's fixed versions. Get started or get a free API key.
curl -sS "https://api.cvefocus.com/v1/check?format=text" -H "Authorization: Bearer $CVEFOCUS_KEY" \ -H "Content-Type: text/plain" --data-binary @inventory.txt
What the vendor says
As published in the CVE record by Radiometer, the CVE's assigner (usually the vendor). Check the vendor's advisory before acting.
- Radiometer Medical Aps ABL90 FLEX and ABL90 FLEX PLUS Analyzers: affected: Application software versions < 3.5MR11 with Windows 7, Windows XP operating systems, Application software versions >= 3.5MR11 with Windows 10 operating system not affected
- Radiometer Medical Aps ABL800 BASIC and ABL800 FLEX Analyzers: affected: Application software versions < 6.20MR2 with Windows 7, Windows XP operating systems, Application software versions >= 6.20MR2 with Windows 10 operating system not affected
- Radiometer Medical Aps AQT90 FLEX Analyzers: affected: Application software versions <= 8.13 MR2 with Windows 7, Windows XP operating systems, Application software versions >= 8.13 MR2 with Windows 10 operating system not affected
Solution: Customers should ensure the following: • The network is secure, and access follows best practices. Local Radiometer representatives will contact all affected customers to discuss a permanent solution.
Workaround: If the network is not considered secure, please remove the analyzer from the network.
References
About this page
Compiled by CVEfocus from the CVE List, the security data and VEX statements of Ubuntu, Debian, Red Hat, AlmaLinux, Rocky Linux and Microsoft, CISA's Known Exploited Vulnerabilities catalog and FIRST EPSS, refreshed several times a day (data status). Information only; see the disclaimer. Official record: cve.org · NVD.