CVEfocus › CVE database › CVE-2025-30651

CVE-2025-30651Junos OS and Junos OS Evolved: Receipt of a specific ICMPv6 packet causes a memory…

CVSS 7.5 HighEPSS 0.8% (higher than 52% of CVEs)Published 2025-04-09Updated 2025-04-09Assigner: juniper

A Buffer Access with Incorrect Length Value vulnerability in the routing protocol daemon (rpd) of Juniper Networks Junos OS and Junos OS Evolved allows an unauthenticated, network-based attacker to cause a Denial of Service (DoS). When an attacker sends a specific ICMPv6 packet to an interface with "protocols router-advertisement" configured, rpd crashes and restarts. Continued receipt of this packet will cause a sustained DoS condition.  This issue only affects systems configured with IPv6. This issue affects Junos OS:  * All versions before 21.2R3-S9,  * from 21.4 before 21.4R3-S10, * from 22.2 before 22.2R3-S6, * from 22.4 before 22.4R3-S4, * from 23.2 before 23.2R2-S2, * from 23.4 before 23.4R2; and Junos OS Evolved: * All versions before 21.2R3-S9-EVO, * from 21.4-EVO before 21.4R3-S10-EVO, * from 22.2-EVO before 22.2R3-S6-EVO, * from 22.4-EVO before 22.4R3-S4-EVO, * from 23.2-EVO before 23.2R2-S2-EVO, * from 23.4-EVO before 23.4R2-EVO.

CWE-805

What to do

None of the Linux distributions or Windows releases we track list an affected package for this CVE. Check the vendor-reported products below.

Is your server affected? One read-only command checks every installed package against this CVE and all others, using each vendor's fixed versions. Get started or get a free API key.

curl -sS "https://api.cvefocus.com/v1/check?format=text" -H "Authorization: Bearer $CVEFOCUS_KEY" \
  -H "Content-Type: text/plain" --data-binary @inventory.txt

What the vendor says

As published in the CVE record by juniper, the CVE's assigner (usually the vendor). Check the vendor's advisory before acting.

Solution: The following software releases have been updated to resolve this specific issue: Junos OS: 21.2R3-S9, 21.4R3-S10, 22.2R3-S6, 22.4R3-S4, 23.2R2-S2, 23.4R2, 24.2R1, and all subsequent releases. Junos OS Evolved: 21.2R3-S9-EVO, 21.4R3-S10-EVO, 22.2R3-S6-EVO, 22.4R3-S4-EVO, 23.2R2-S2-EVO, 23.4R2-EVO, 24.2R1-EVO, and all subsequent releases.

Workaround: There are no known workarounds for this issue. A firewall filter can be implemented to restrict ICMPv6 traffic.

Vendor advisories:

References

About this page

Compiled by CVEfocus from the CVE List, the security data and VEX statements of Ubuntu, Debian, Red Hat, AlmaLinux, Rocky Linux and Microsoft, CISA's Known Exploited Vulnerabilities catalog and FIRST EPSS, refreshed several times a day (data status). Information only; see the disclaimer. Official record: cve.org · NVD.