CVEfocus › CVE database › CVE-2025-59105

CVE-2025-59105Unencrypted Flash Storage in dormakaba access manager

CVSS 7.0 HighEPSS 0.1% (higher than 0% of CVEs)Published 2026-01-26Updated 2026-01-26Assigner: SEC-VLab

With physical access to the device and enough time an attacker can desolder the flash memory, modify it and then reinstall it because of missing encryption. Thus, essential files, such as "/etc/passwd", as well as stored certificates, cryptographic keys, stored PINs and so on can be modified and read, in order to gain SSH root access on the Linux-based K7 model. On the Windows CE based K5 model, the password for the Access Manager can additionally be read in plain text from the stored SQLite database.

CWE-312

What to do

None of the Linux distributions or Windows releases we track list an affected package for this CVE. Check the vendor-reported products below.

Is your server affected? One read-only command checks every installed package against this CVE and all others, using each vendor's fixed versions. Get started or get a free API key.

curl -sS "https://api.cvefocus.com/v1/check?format=text" -H "Authorization: Bearer $CVEFOCUS_KEY" \
  -H "Content-Type: text/plain" --data-binary @inventory.txt

What the vendor says

As published in the CVE record by SEC-VLab, the CVE's assigner (usually the vendor). Check the vendor's advisory before acting.

Solution: A firmware update to at least BAME 06.00.x RA is recommended. Hardware access and special equipment are required to exploit this vulnerability. In general, the Access Manager should be installed in a secured area and protected by a tamper contact.

Vendor advisories:

References

About this page

Compiled by CVEfocus from the CVE List, the security data and VEX statements of Ubuntu, Debian, Red Hat, AlmaLinux, Rocky Linux and Microsoft, CISA's Known Exploited Vulnerabilities catalog and FIRST EPSS, refreshed several times a day (data status). Information only; see the disclaimer. Official record: cve.org · NVD.