CVE-2026-12562Toptech Systems RCU II+ and Multiload II+ Missing Authentication for Critical Function
The RCU II+ and Multiload II+ are vulnerable to an unauthenticated service that exposes a debug interface granting full root-level access to the embedded system. This vulnerability stems from a network-accessible port running a Target Communications Framework (TCF) service that does not require any authentication, allowing an attacker to directly interact with the Linux environment that powers the device. Once connected, an attacker can freely view and modify the filesystem, manipulate running processes, and control network interfaces, enabling deep alteration of system behavior.
What to do
None of the Linux distributions or Windows releases we track list an affected package for this CVE. Check the vendor-reported products below.
Is your server affected? One read-only command checks every installed package against this CVE and all others, using each vendor's fixed versions. Get started or get a free API key.
curl -sS "https://api.cvefocus.com/v1/check?format=text" -H "Authorization: Bearer $CVEFOCUS_KEY" \ -H "Content-Type: text/plain" --data-binary @inventory.txt
What the vendor says
As published in the CVE record by icscert, the CVE's assigner (usually the vendor). Check the vendor's advisory before acting.
- Toptech Systems RCU II+: affected: before 2025-11-24; fixed in
2025-11-24 - Toptech Systems Multiload II+: affected: before 2025-11-24; fixed in
2025-11-24
Solution: Toptech Systems provides two methods for remediating affected RCU II+ and Multiload II+ units: First, move the device to a closed or segmented network without untrusted access. Run one of the RCU II+/Multiload II+ Vulnerability Removal Tools (VRT) available at https://s3.amazonaws.com/docs.toptech.com/nonpublic/rcuiip_mliip_vrt.zip , https://s3.amazonaws.com/docs.toptech.com/nonpublic/rcuiip_mliip_vrt.gz. * This option does not require breaking Weights and Measures seals and has the least operational impact. Install the latest firmware from https://s3.amazonaws.com/docs.toptech.com/index.html#downloads/Firmware/RCUII+_MLII+_SMPII+/ . * This method requires stopping the bay and breaking the W&M seal. Be sure to back up the current ML configuration before performing the firmware update. For questions, contact Toptech Systems Support at security@toptech.com. Additional details are…
References
- https://s3.amazonaws.com/docs.toptech.com/nonpublic/rcuiip_mliip_vrt.zip
- https://s3.amazonaws.com/docs.toptech.com/nonpublic/rcuiip_mliip_vrt.gz
- https://s3.amazonaws.com/docs.toptech.com/index.html#downloads/Firmware/RCUII+_MLII+_SMPII+/
- https://s3.amazonaws.com/docs.toptech.com/nonpublic/2025%2012%2001%20RCU%20IIPlus%20MultiLoad%20IIPlus%20Vulnerability%20Notice.pdf
- https://www.cisa.gov/news-events/ics-advisories/icsa-26-211-03
- https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-211-03.json
About this page
Compiled by CVEfocus from the CVE List, the security data and VEX statements of Ubuntu, Debian, Red Hat, AlmaLinux, Rocky Linux and Microsoft, CISA's Known Exploited Vulnerabilities catalog and FIRST EPSS, refreshed several times a day (data status). Information only; see the disclaimer. Official record: cve.org · NVD.