CVEfocus › CVE database › CVE-2026-133851

CVE-2026-133851FlowIntel Alerting: Missing Private Case Authorization Check Allows Connector Owners to…

CVSS 5.3 MediumEPSS 0.3% (higher than 17% of CVEs)Published 2026-11-20Updated 2026-11-20Assigner: CIRCL

FlowIntel's alerting module contained an authorization bypass in the alert access control logic. When an alert was linked to a private case, the system relied solely on connector ownership (user or organization) to determine access, without verifying that the requesting user still held valid membership in the associated private case. This meant that a user who was a connector owner of an alert could continue to read alert details, review history, raw payloads, and action comments, and could perform review-status updates or case-creation actions, even after their access to the linked private case had been revoked or they were never a member of that case. Additionally, a time-of-check to time-of-use (TOCTOU) gap existed: after a review-status update or a competing case-creation claim was committed, the response could disclose private case identifiers or review history to a user whose access had been concurrently removed by another session linking the alert to a private case. Impact: - Unauthorized disclosure of private case data (review comments, raw payloads, action history) through alert endpoints. - Unauthorized modification of alert review status and creation of cases from alerts the user should no longer access. - Leakage of a competing case identifier to an unauthorized user during concurrent case-creation races. Affected versions: FlowIntel prior to 4.1.0.

CWE-362CWE-862

What to do

None of the Linux distributions or Windows releases we track list an affected package for this CVE. Check the vendor-reported products below.

Is your server affected? One read-only command checks every installed package against this CVE and all others, using each vendor's fixed versions. Get started or get a free API key.

curl -sS "https://api.cvefocus.com/v1/check?format=text" -H "Authorization: Bearer $CVEFOCUS_KEY" \
  -H "Content-Type: text/plain" --data-binary @inventory.txt

What the vendor says

As published in the CVE record by CIRCL, the CVE's assigner (usually the vendor). Check the vendor's advisory before acting.

Solution: The fix enforces private case visibility as a mandatory gate before any connector-ownership check can grant alert access. If an alert is linked to a private case and the user cannot view that case, access is denied regardless of ownership. A post-commit re-verification is added after review-status updates and after detecting a competing case-creation claim, ensuring that concurrent association changes do not result in unauthorized data disclosure in the response.

Vendor advisories:

References

About this page

Compiled by CVEfocus from the CVE List, the security data and VEX statements of Ubuntu, Debian, Red Hat, AlmaLinux, Rocky Linux and Microsoft, CISA's Known Exploited Vulnerabilities catalog and FIRST EPSS, refreshed several times a day (data status). Information only; see the disclaimer. Official record: cve.org · NVD.