CVE-2026-15422SCTP needs to better-check INIT ACK chunk parameters
The illumos SCTP inbound path performs association lookup for INIT ACK chunks without adequately validating the address parameters carried in the chunk. Since this lookup runs during packet classification (i.e. before SCTP integrity checks or IPsec policy are applied) a remote, unauthenticated attacker can send a crafted SCTP INIT ACK packet with malformed address parameters to cause an out-of-bounds access and kernel heap corruption, which may lead to remote code execution. The flaw has existed since 2010 (illumos-gate commit a5407c02), and affects any illumos distribution prior to illumos-gate commit 53a3efde.
What to do
None of the Linux distributions or Windows releases we track list an affected package for this CVE. Check the vendor-reported products below.
Is your server affected? One read-only command checks every installed package against this CVE and all others, using each vendor's fixed versions. Get started or get a free API key.
curl -sS "https://api.cvefocus.com/v1/check?format=text" -H "Authorization: Bearer $CVEFOCUS_KEY" \ -H "Content-Type: text/plain" --data-binary @inventory.txt
What the vendor says
As published in the CVE record by illumos, the CVE's assigner (usually the vendor). Check the vendor's advisory before acting.
- illumos-gate: affected: a5407c02d5ed61b29481b9b71f1307d7ebec9e5c to before 53a3efdeff8e6745bbfb69c5360f94962fb79e75; fixed in
53a3efdeff8e6745bbfb69c5360f94962fb79e75 - OmniOS: affected: r151058 to before r151058j, r151056 to before r151056aj, r151054 to before r151054bj, any to before r151054
- Triton Data Center SmartOS: affected: any to before 202060709; fixed in
202060709,20260709
Solution: Update your illumos distro to one that includes 18117's fix.
Workaround: In order of recommendation: 1.) Hotpatch the faulty SCTP input path. See the illumos issue for the hotpatch technique. If the function to patch does not exist, the issue has been fixed. If the output does not match the illumos issue's output, contact developers@lists.illumos.org. 2.) Use ipfilter per-netstack or perimeter firewalls to drop SCTP packets. IMPORTANT NOTE: any entity inside an SCTP-dropping firewall perimeter can still attack.
Vendor advisories:
References
- https://illumos.topicbox.com/groups/developer/Ta1a8e2e1f7f928df/18117-sctp-needs-to-better-check-init-ack-chunk-parameters
- https://illumos.org/issues/18117
- https://github.com/illumos/illumos-gate/commit/53a3efdeff8e6745bbfb69c5360f94962fb79e75
About this page
Compiled by CVEfocus from the CVE List, the security data and VEX statements of Ubuntu, Debian, Red Hat, AlmaLinux, Rocky Linux and Microsoft, CISA's Known Exploited Vulnerabilities catalog and FIRST EPSS, refreshed several times a day (data status). Information only; see the disclaimer. Official record: cve.org · NVD.